DuPont™ Vertrel® X-DA is a specially designed displacement drying product developed by DuPont for one-step, low-energy, spot-free drying that is efficient, safe to use, and environmentally responsible. DuPont™ Vertrel® X-DA consists of DuPont™ Vertrel® XF, a fluorosurfactant additive, and an antistatic additive.
Applications
DuPont™ Vertrel® MCA Plus is widely used for the following applications:
- Defluxing
- Heavy Soil Removal
- Light Soil Removal
- Oxygen Service Cleaning
- Precision Cleaning
Compatibility and Soils
DuPont™ Vertrel® MCA Plus is compatible with most plastics and elastomers and can be used to clean a wide variety of soils including cutting oils, gear oils, heavy greases, hydraulic oils, stamping oils, synthetic oils, vacuum oils, waxes, and mineral oils.
Environmental Properties
DuPont™ Vertrel® has zero ozone-depletion potential and low global warming potential. It is used extensively to replace CFC-113, methyl chloroform, hydrochlorofluorocarbons (HCFCs), and perfluorocarbons (PFCs) in several applications.
DuPont™ Vertrel® MCA Plus has been accepted by the U.S. Environmental Protection Agency (EPA) under the Significant New Alternatives Policy (SNAP) program, as a substitute for ozone-depleting substances. DuPont™ Vertrel® MCA Plus is not a hazardous air pollutant (HAP) and is therefore not subject to NESHAP regulations. DuPont™ Vertrel® MCA Plus is not included in the SARA Title III Section 313 list of toxic chemicals, and is not subject to SARA Title III (EPCRA) reporting requirements.
The components of DuPont™ Vertrel® MCA Plus are listed in the TSCA inventory. One component, HFC-43-10mee, is subject to the Significant New Use Rule (SNUR) and should be used only in the applications indicated in the DuPont™ Vertrel® MCA Plus MSDS regulatory section.
Flammability and Toxicity
DuPont™ Vertrel® MCA Plus exhibits no closed-cup flash point per the Pensky-Martens Closed Cup Tester (ASTM D93) and is not classified as a flammable liquid by NFPA or DOT. However the product does exhibit vapor flammability limits in air. Users should clear equipment of all vapors and liquids before performing any maintenance operations that may result in an ignition source.
Flash point data and limits of flammability in air provide the user with additional information that should be used as elements of a fire risk assessment and to determine guidelines for safe handling of volatile chemicals. Users should ensure compliance with NFPA standards and local fire codes.
Acute toxicity studies show that DuPont™ Vertrel® MCA Plus has low toxicity. It could pose a slight skin and eye irritation and has low inhalation toxicity. |